Series 5500 Advanced & Alternate Installation Instructions
STEP #2 INSTALL SETTING BLOCKS AND PRESET GASKETS INTO MULLIONS
A. Apply the setting blocks at the bottom of the spandrel lites per the approved shop
drawings.
B. Install the preset glazing gaskets per “Glazing Preparation” in Section IV of the
Standard Installation Instructions, except the gaskets will be set on the
interior
side
of the glazing pocket as shown below.
FLOOR SLAB
VISION AREAS
VISION AREAS
SPANDREL AREAS
SPLICE JOINT
EXTERIOR VIEW
Section VII: Glazing at Spandrel Areas of I.G. Frames